- Non disponibile
CONTATTORE 4P NO 45A AC1
LOVBF26T4D024
1
136,96 €
Tasse incluse
Paga in sicurezza con PayPal
Spedizione in 1-2 giorni lavorativi
LOVBF26T4D024
Product designation | Power contactor | |||
Product type designation | BF26 | |||
Contact characteristics | ||||
Number of poles | Nr. | 4 | ||
Rated insulation voltage Ui IEC/EN | V | 690 | ||
Rated impulse withstand voltage Uimp | kV | 6 | ||
Operational frequency | ||||
min | Hz | 25 | ||
max | Hz | 400 | ||
IEC Conventional free air thermal current Ith | A | 45 | ||
Operational current Ie | ||||
AC-1 (<=40°C) | A | 45 | ||
AC-1 (<=55°C) | A | 36 | ||
AC-1 (<=70°C) | A | 32 | ||
AC-3 (<=440V <=55°C) | A | 26 | ||
AC-4 (400V) | A | 11.5 | ||
Rated operational power AC-1 (T<=40°C) | ||||
230V | kW | 17 | ||
400V | kW | 30 | ||
500V | kW | 37 | ||
690V | kW | 51 | ||
IEC max current Ie in DC1 with L/R <= 1ms with 1 poles in series | ||||
<=24V | A | 25 | ||
48V | A | 21 | ||
75V | A | 18 | ||
110V | A | 6 | ||
220V | A | |||
IEC max current Ie in DC1 with L/R <= 1ms with 2 poles in series | ||||
<=24V | A | 28 | ||
48V | A | 28 | ||
75V | A | 25 | ||
110V | A | 22 | ||
220V | A | 2 | ||
IEC max current Ie in DC1 with L/R <= 1ms with 3 poles in series | ||||
<=24V | A | 28 | ||
48V | A | 28 | ||
75V | A | 25 | ||
110V | A | 24 | ||
220V | A | 20 | ||
IEC max current Ie in DC1 with L/R <= 1ms with 4 poles in series | ||||
<=24V | A | 28 | ||
48V | A | 28 | ||
75V | A | 25 | ||
110V | A | 24 | ||
220V | A | 26 | ||
IEC max current Ie in DC3-DC5 with L/R <= 15ms with 1 poles in series | ||||
<=24V | A | 18 | ||
48V | A | 15 | ||
75V | A | 13 | ||
110V | A | 2 | ||
220V | A | |||
IEC max current Ie in DC3-DC5 with L/R <= 15ms with 2 poles in series | ||||
<=24V | A | 20 | ||
48V | A | 20 | ||
75V | A | 18 | ||
110V | A | 13 | ||
220V | A | 3 | ||
IEC max current Ie in DC3-DC5 with L/R <= 15ms with 3 poles in series | ||||
<=24V | A | 25 | ||
48V | A | 25 | ||
75V | A | 20 | ||
110V | A | 18 | ||
220V | A | 19 | ||
IEC max current Ie in DC3-DC5 with L/R <= 15ms with 4 poles in series | ||||
<=24V | A | 30 | ||
48V | A | 30 | ||
75V | A | 25 | ||
110V | A | 20 | ||
220V | A | 15 | ||
Short-time allowable current for 10s (IEC/EN60947-1) | A | 210 | ||
Protection fuse | ||||
gG (IEC) | A | 50 | ||
aM (IEC) | A | 32 | ||
Making capacity (RMS value) | A | 260 | ||
Breaking capacity at voltage | ||||
440V | A | 208 | ||
500V | A | 184 | ||
690V | A | 168 | ||
Resistance per pole (average value) | m? | 2 | ||
Power dissipation per pole (average value) | ||||