CONTATTORE 3P +1NO 38A AC3 24V
LOVBF3800A024
0
127,93 €
Tasse incluse
Paga in sicurezza con PayPal
Spedizione in 1-2 giorni lavorativi
LOVBF3800A024
Product designation | Power contactor | |||
Product type designation | BF38 | |||
Contact characteristics | ||||
Number of poles | Nr. | 3 | ||
Rated insulation voltage Ui IEC/EN | V | 690 | ||
Rated impulse withstand voltage Uimp | kV | 6 | ||
Operational frequency | ||||
min | Hz | 25 | ||
max | Hz | 400 | ||
IEC Conventional free air thermal current Ith | A | 56 | ||
Operational current Ie | ||||
AC-1 (<=40°C) | A | 56 | ||
AC-1 (<=40°C) with 16mm² wire and fork end lug | A | 60 | ||
AC-1 (<=55°C) | A | 45 | ||
AC-1 (<=55°C) with 16mm² wire and fork end lug | A | 48 | ||
AC-1 (<=70°C) | A | 40 | ||
AC-1 (<=70°C) with 16mm² wire and fork end lug | A | 42 | ||
AC-3 (<=440V <=55°C) | A | 38 | ||
AC-4 (400V) | A | 15.5 | ||
Rated operational power AC-3 (T<=55°C) | ||||
230V | kW | 11 | ||
400V | kW | 18.5 | ||
415V | kW | 18.5 | ||
440V | kW | 18.5 | ||
500V | kW | 20 | ||
690V | kW | 22 | ||
Rated operational power AC-1 (T<=40°C) | ||||
230V | kW | 21 | ||
400V | kW | 36 | ||
500V | kW | 45 | ||
690V | kW | 62 | ||
IEC max current Ie in DC1 with L/R <= 1ms with 1 poles in series | ||||
<=24V | A | 35 | ||
48V | A | 30 | ||
75V | A | 23 | ||
110V | A | 8 | ||
220V | A | |||
IEC max current Ie in DC1 with L/R <= 1ms with 2 poles in series | ||||
<=24V | A | 36 | ||
48V | A | 34 | ||
75V | A | 29 | ||
110V | A | 32 | ||
220V | A | 4 | ||
IEC max current Ie in DC1 with L/R <= 1ms with 3 poles in series | ||||
<=24V | A | 36 | ||
48V | A | 34 | ||
75V | A | 33 | ||
110V | A | 34 | ||
220V | A | 30 | ||
IEC max current Ie in DC1 with L/R <= 1ms with 4 poles in series | ||||
<=24V | A | 36 | ||
48V | A | 34 | ||
75V | A | 33 | ||
110V | A | 34 | ||
220V | A | 38 | ||
IEC max current Ie in DC3-DC5 with L/R <= 15ms with 1 poles in series | ||||
<=24V | A | 24 | ||
48V | A | 20 | ||
75V | A | 17 | ||
110V | A | 2,5 | ||
220V | A | |||
IEC max current Ie in DC3-DC5 with L/R <= 15ms with 2 poles in series | ||||
<=24V | A | 28 | ||
48V | A | 25 | ||
75V | A | 22 | ||
110V | A | 18 | ||
220V | A | 3 | ||
IEC max current Ie in DC3-DC5 with L/R <= 15ms with 3 poles in series | ||||
<=24V | A | 32 | ||
48V | A | 28 | ||
75V | A | 28 | ||
110V | A | 23 | ||
220V | A | 25 | ||
IEC max current Ie in DC3-DC5 with L/R <= 15ms with 4 poles in series | ||||
<=24V | A | 32 | ||
48V | A | 28 | ||
75V | A | 28 | ||
110V | A | 23 | ||
220V | A | 15 | ||
Short-time allowable current for 10s (IEC/EN60947-1) | A |